LM2HQMC Deep UV LED

  • Product features:High reliability, long life, environmental protection and energy saving, ultra-high light power, concentration and high efficiency sterilization & nbsp;
  • Application fields:Sterilization and disinfection (especially dynamic water sterilization and air sterilization), medical phototherapy, optical sensor, biological analysis / detection

SKU: LM2HQMC Category:

Description

  • Product photos
LM2HQMC LM2HQMC
  • Device structure

LM2HQMC


LM2HQMC

Circuit connection

LM2HQMC

Recommended pad


  • A single device contains two kinds of chips, UVC and zener diode. Zener diode can protect UVC from ESD;
  • The positive and negative pole marks are as shown in the above figure. The front gap is the negative pole, the back corner is the negative pole, and the round hole end of the taped product is the negative pole;
  • Drawing unit: mm, unless otherwise specified, dimensional tolerance is ± 0.20 mm
  • Package: 6565 package, external dimension: 6.5 × 6.5 × 3.4 (L × w × h) [unit: mm]
  • Package material: AlN ceramic bracket, conjoined convex lens
  • Photoelectric characteristic parameters

UVC photoelectric parameters and spec range (@ 400mA, Ta = 25 ℃, Rh = 30%)

Item Symbol Min. Typ. Max. Bin Unit
Peak wavelength λp 260 / 280 Such as groups nm
Optical power P0 80 / 150 / mW
working voltage Vf 10 / 14 1 V
Driving current If / 400 / / mA
Irritation angle 2θ1/2 / 30 / / deg.
FWHM of wave crest Δλ 7 / 13 / nm
thermal resistance RΘj-b / 20 / / ℃/W

Wavelength range

Groups W01 W02
Wavelength (nm) 260~270 270~280

Optical power range

Groups P205 P255 P256
Optical power (MW) 80~100 100~125 125~150

Voltage range

Groups VG1 VG2 VG3 VG4
Voltage (V) 10~11 11~12 12~13 13~14

Limit conditions

parameter Symbol numerical value Company
power waste Pd 8400 mW
Forward current If 600 mA
Forward voltage Vf 5~7 V
Service temperature TOPR -30~60 ℃
Storage temperature TSTG -40~100 ℃
Junction temperature Tj 80 ℃
Static electricity (human mode) ESD 2000 V
  • Optical power refers to the total optical output power collected by integrating sphere;
  • The measurement errors of forward voltage, peak wavelength and radiation power are ± 0.2V, ± 3nm and ± 10%, respectively. The increase of injection current will lead to temperature rise, The light attenuation of LED lamp beads will be accelerated, and the service life will be shortened; when the LED lamp beads are tested or used beyond the above limit values, the reliability of the device may be affected and permanent damage may be caused.
  • It is recommended to provide a good cooling environment or cooling system to obtain the best effect.
  • Legend of photoelectric parameters
LM2HQMC
  • The above test data are from DUVTek, and the actual curve will be different depending on the sampling situation.
  • Reflow soldering
Reflow soldering profile
  • The patch shall be reflowed with environment-friendly solder paste,The peak temperature should not be greater than 260 ℃The peak time should be controlled within 10 seconds, and the reflux time should not exceed 8 minutes.
  • Reflow welding should not be more than once;
  • It is not recommended to repair after welding dark purple led. When repair is inevitable, double head soldering iron must be used, and the product itself should not be damaged while operating carefully;
  • When welding, do not apply pressure on the deep UV LED during heating;
  • It is recommended to use convection reflow welder with temperature above 7.
  • Packaging specification

Packing instructions

Carrier
Reel
Aluminum foil bag packaging
  • The camber angle of the carrier is not more than 1 mm / 100 mm, and the length is 250 mm;
  • All dimensions meet eia-481-b requirements;
  • Materials: conductive polyester polystyrene plastic.

Label description

label interpretation
TYPE
SPEC Wxxpxxxvxxa1, please refer to spec scope for specific meaning
LOTS Batch number
QTY number
Date date
  • Reliability test
Test items experimental condition standard Failure ratio
Normal temperature aging T = 25 ℃, calibration current, continuous lighting for 1000 hours ΔPo≤15%,ΔVF≤20% 0/10
Thermal Shock -300 cycles of cold and hot shock at 40~+100 ℃, 30min/cycle ΔPo≤15%,ΔVF≤20% 0/10
Antistatic R=1.5kΩ, C=100pF,Voltage level=2kV ΔPo≤15%,ΔVF≤20% 0/10
  • Human protection
Human protection
  • All assembly workers, observers and bystanders must have eye and skin protection;
  • It is forbidden to observe with naked eyes (including through microscope) and handle deep UV LED naked in operation;
  • Do not touch the optical structure of the deep UV lamp bead;
  • This product is a humidity sensitive product, the recommended storage temperature is 18 ℃~ 30 ℃, the humidity is 30% ~ 60%, and sealed. In order to ensure the product quality, it is recommended to use it within one year after leaving the factory if the outer packing bag is not opened; if the outer packing bag is opened, it is recommended to use it within 24 hours, and re seal it for storage after 24 hours. Dehumidification measures should be taken before the next use: temperature: 65 ℃ time: 5h.